Home » F1000-G SERIES AC Drives(0.4-400K)

F1000-G SERIES AC Drives(0.4-400K)

F1000-G series has the advantage of high using rate of voltage, high power factor, good dynamic performance, high precision, low-noise and large-torque. Especially because of the random carrier method, the products have the capability of low noise at low frequency. Moreover, it also has the capability of coding speed control and linear speed display, and so on. F1000-G can be widely used for the fields of spinning and weaving, printing and dyeing, food, medicine and Mechanical electron.
Main Function of this AC Drives:
1. Combination of 16 microprocessors, space voltage vector control and random PWM control.
2. Capability of torque elevation and automatic slip compensation.
3. Output frequency 0.50-400.0Hz, the highest resolution is 0.01Hz.
4. Low-noise and random carrier.
5. Multi-speed control and jogging running.
Model Applicable
Motor (kw)
Rated Current
Output (A)
Structure Code Cooling Mode Remarks
F1000-G0004S2B 0.4 2.5 B0 Self-cooling Single-Phase Plastic Hanging
F1000-G0007S2B 0.75 4.5 B0 Air Cooling
F1000-G0007XS2B 0.75 4.5 B0 Air Cooling
F1000-G0015S2B 1.5 7 B2 Air Cooling
F1000-G0015XS2B 1.5 7 B2 Air Cooling
F1000-G0022S2B 2.2 10 B3 Air Cooling
F1000-G0007T3B 0.75 2 B2 Air Cooling Three-Phase Plastic Hanging
F1000-G0015T3B 1.5 4 B2 Air Cooling
F1000-G0022T3B 2.2 6.5 B2 Air Cooling
F1000-G0037T3B 3.7 8 B4 Air Cooling
F1000-G0040T3B 4.0 9 B4 Air Cooling
F1000-G0055T3B 5.5 12 B5 Air Cooling
F1000-G0075T3B 7.5 17 B5 Air Cooling
F1000-G0110T3C 11 23 C1 Air Cooling Three-Phase Metal Hanging
F1000-G0150T3C 15 32 C2 Air Cooling
F1000-G0185T3C 18.5 38 C3 Air Cooling
F1000-G0220T3C 22 44 C3 Air Cooling
F1000-G0300T3C 30 60 C4 Air Cooling
F1000-G0370T3C 37 75 C5 Air Cooling
F1000-G0450T3C 45 90 C5 Air Cooling
F1000-G0550T3C 55 110 C6 Air Cooling
F1000-G0750T3C 75 150 C6 Air Cooling
F1000-G0900T3C 90 180 C7 Air Cooling
F1000-G1100T3C 110 220 C7 Air Cooling
F1000-G1320T3C 132 265 C8 Air Cooling
F1000-G1600T3C 160 320 C8 Air Cooling
F1000-G1100T3D 110 220 D0 Air Cooling Three-Phase Metal Cabinet
F1000-G1320T3D 132 265 D1 Air Cooling
F1000-G1600T3D 160 320 D1 Air Cooling
F1000-G2000T3D 200 400 D2 Air Cooling
F1000-G2200T3D 220 440 D2 Air Cooling
F1000-G2500T3D 250 490 D3 Air Cooling
F1000-G2800T3D 280 550 D3 Air Cooling
F1000-G3150T3D 315 620 D3 Air Cooling
F1000-G3550T3D 355 700 D3 Air Cooling
F1000-G4000T3D 400 800 D4 Air Cooling
Technical Specifications for F1000–G Series Inverters
Items Contents
Input Rated Voltage Range 3-phase 400V±15%;
single-phase 230V±15%
Rated Frequency 50/60Hz
Output Rated Voltage Range 3-phase 0~400V;3-phase 0~230V
Frequency Range 0.50~400.0Hz
V/Control Control Mode Linear V/F control; space voltage vector+random PWM
Frequency Resolution Max 0.01Hz, adjustment allowed
Torque Promotion Torque Promotion curve (V/F) can be set within 1~16;
Stall Prevention Current output is restricted, and threshold
current can be adjusted.
Overload Capacity 150% rated current,1minute
Operation Function Frequency Setting Potentiometer or external analog signal (0~5V, 0~10V, 0~20mA); keypad (terminal)▲/▼ keys, external control logic and PLC setting.
Start/Stop Control Passive contact switch control or keypad control
Frequency Change Rate 0.1~3000S (time required for certain frequency change)
Protection Function Input out-phase, input under-voltage, DC over-voltage, over-current, over-load, current stall, over-heat, external disturbance
Display LED nixie tube showing present output frequency, present rotate-speed (rpm), present output current, present output voltage, present linear-velocity, types of faults, and parameters for the system and operation; LED indicators showing the current working status of inverter.
Environment Conditions Equipment Location Free of tangy caustic gases or dust
Environment Temperature -10℃ ~+50℃
Environment Humidity Below 90% (no water-bead coagulation)
Vibration Strength Below 0.5g (acceleration)
Height above sea level 1000m or below
Applicable Motor 0.4~400KW